Following are the general points to remember for civil site
engineers to make the construction work easier while monitoring quality of
construction related to reinforcement work,
- Lapping is allowed for the bars having diameters more than 36 mm.
- Chair rod maximum spacing is 1.00m (or) 1 no per 1m2
- For dowels rod minimum of 12mm diameter should be used.
- Chairs minimum of 12mm diameter should be used.
- Longitudinal reinforcement not less than 0.8% and more than 6% of Cross C/S
- Minimum bars for square column is 4 no’s and 6 no’s for circular column.
- Main bars in the slab shall not be less than 8mm (HYSD) or 10mm (main bars) and the distributors not less than 8mm and note more than 1/8 of slab thickness.
- Minimum thickness of slab is 125mm ()
- Dimension tolerance for cubes + 2 mm
- Free fall of concrete is allowed maximum to 1.50m.
- Lap slices not be used for bar larger than 36mm.
- Water absorption of bricks should not be more than 15%
- PH value of the water should not be less than 6
- Compressive strength of bricks is 3.5 N/mm2
- In steel reinforcement binding wire required is 8 kg per MT

Wow, really informative points to be remember. Thanks a lot for the share. Villas in coimbatore | Individual villas in coimbatore | Villas in kovaipudur